Western States Distributors
Home
View Cart
My Account
Help
ENAMELWARE
FABRIC
NEW ITEMS
Nu Trendz
PLASTIC BASINS, TRAYS, BOWLS
RIT DYE
SHEEP CAMP
STOCK POTS & STEAMER POTS
WOOD CUTTING
BLANKETS
AUTOMOTIVE
Category
LUGGAGE
NUTS, BOLTS, & FASTENERS
PEST CONTROL
TABLE COVER ROLLS
HAND TOOLS
POWER TOOLS & ACC
FASTENERS
HARDWARE
PAINT & SUNDRIES
ELECTRICAL
PLUMBING
HEATING & COOLING
HOUSEWARES
LAWN & GARDEN
SPORTING GOODS
STORE SUPPLIES
DOLLAR CENTRAL
PET & WILD BIRD
FARM & RANCH
OUTDOOR LIVING & PATIO
Specialty
APPAREL
CLOSEOUTS
FAIRS AND FRYBREAD
IMPULSE ITEMS
KITCHEN UTENSILS, GADGETS & ACCESSORIES
SEWING AND CRAFT
TOYS
Home
>
ELECTRICAL
>
ROUGH ELECTRICAL
>
FUSES & BREAKERS
>
CIRCUIT BREAKERS - ARC FAULT
Sort By:
Price: Low to High
Price: High to Low
Most Popular
Title
Manufacturer
Newest
Oldest
Availability
10 per page
20 per page
40 per page
60 per page
100 per page
1
2
Siemens QA120AFC Circuit Breaker, AFCI, Combination, 20 A, 1 -Pole, 120/240 V, Fixed Trip, Plug Mounting
Wholesale Price:
(Members Only)
Plug-in, combination type CAFCI circuit breaker, complies with the requirements for both branch/feeder and outlet circuit CAFCIs. Required on January 1, 2008 by 2005 NEC, combination type CAFCI circuit breakers must be placed on bedroom power and lighting circuits. Protects downstream branch circuit wiring and cord sets and power supply cords. Provides ARC fault, overload and short circuit protection. UL listed. Protects against worn electrical insulation or damaged wire, misapplied or damaged plug-in appliances and equipment and loose electrical connections. 2 LEDs appear for 5 secs each time the CAFCI is turned on, up to 30 days after the last trip to indicate last known trip condition. One LED means arcing fault. Two LEDs means arcing fault to ground. 10 kA interrupting rating. UL listed, 120 VAC. Wire range 14 to 8 AWG. 1 in space, 120 V.
Square D HOM120CAFIC Circuit Breaker, AFCI, Combination, 20 A, 1 -Pole, 120 V, Fixed Trip, Plug Mounting
Wholesale Price:
(Members Only)
Single-pole 1 in combination CAFCI circuit breaker is designed for arc-fault, overload and short-circuit protection of an electrical system. Designed to detect arcs that are caused by damaged, aged or improperly used wires or cords and to disconnect the power. With Time-Saver Diagnostics, advanced trip indication technology, identifying the type of fault that last occurred. White push to test button. 10 kA interrupting rating. Rated for 120 VAC. Meets Canadian Electrical code. Carded.
Square D HOM115CAFIC Circuit Breaker, AFCI, Combination, 15 A, 1 -Pole, 120 V, Fixed Trip, Plug Mounting
Wholesale Price:
(Members Only)
Single-pole 1 in combination CAFCI circuit breaker is designed for arc-fault, overload and short-circuit protection of an electrical system. Designed to detect arcs that are caused by damaged, aged or improperly used wires or cords and to disconnect the power. With Time-Saver Diagnostics, advanced trip indication technology, identifying the type of fault that last occurred. White push to test button. 10 kA interrupting rating. Rated for 120 VAC. Meets Canadian Electrical code. Carded.
Siemens QA115AFC Circuit Breaker, AFCI, Combination, 15 A, 1 -Pole, 120/240 V, Fixed Trip, Plug Mounting, Black
Wholesale Price:
(Members Only)
Plug-in, combination type CAFCI circuit breaker, complies with the requirements for both branch/feeder and outlet circuit CAFCIs. Required on January 1, 2008 by 2005 NEC, combination type CAFCI circuit breakers must be placed on bedroom power and lighting circuits. Protects downstream branch circuit wiring and cord sets and power supply cords. Provides ARC fault, overload and short circuit protection. UL listed. Protects against worn electrical insulation or damaged wire, misapplied or damaged plug-in appliances and equipment and loose electrical connections. 2 LEDs appear for 5 secs each time the CAFCI is turned on, up to 30 days after the last trip to indicate last known trip condition. One LED means arcing fault. Two LEDs means arcing fault to ground. 10 kA interrupting rating. UL listed, 120 VAC. Wire range 14 to 8 AWG. 1 in space, 120 V.
GE THQL1115AFP2 Circuit Breaker, AFCI, 15 A, 2-Pole, 120/240 V, Plug
Wholesale Price:
(Members Only)
Provides ARC fault, parallel, ground, Series, overload and short circuit protection. Required for bedroom receptacles effective January 1, 2002. Plug in design with color-coded screws and dual function test button. 120/240 V. 1 in space per breaker.
GE THQL1120AFP2 Circuit Breaker, AFCI, 20 A, 2-Pole, 120/240 V, Plug
Wholesale Price:
(Members Only)
Provides ARC fault, parallel, ground, Series, overload and short circuit protection. Required for bedroom receptacles effective January 1, 2002. Plug in design with color-coded screws and dual function test button. 120/240 V. 1 in space per breaker.
Cutler-Hammer BRP120AF Circuit Breaker, Type BR, 20 A, 1 -Pole, 120 VAC, Instantaneous, Long Time Trip
Wholesale Price:
(Members Only)
Cutler-Hammer Circuit Breaker, Type BR, 120 VAC, 20 A, 1 ph, 1 Pole, 10,000 A Interrupt, Instantaneous, Long Time Trip, 14 to 4 AWG Wire, Plug Mounting, Dimensions: 6 in L x 3-1/2 in W x 1-1/8 in H, Suitable for: Type BR Load Center
Eaton BRN115AF Circuit Breaker, Type BR, 15 A, 1-Pole, 120/240 V, Instantaneous, Long Time Trip, Pigtail
Wholesale Price:
(Members Only)
Eaton Circuit Breaker, Type BR, 120/240 V, 15 A, Number of Phases: 1, Number of Poles: 1, Interrupt Rating: 10 kA, Actuator Type: Magnetic, Thermal, Trip Type: Instantaneous, Long Time, Wire Size: 14 to 8 AWG, Pigtail Mounting, Dimensions: 6 in L x 3-1/2 in W x 1-1/4 in H, Suitable for: EATON Type BR Loadcenters
Eaton BRN120AF Circuit Breaker, Type BR, 20 A, 1-Pole, 120/240 V, Instantaneous, Long Time Trip, Pigtail
Wholesale Price:
(Members Only)
Eaton Circuit Breaker, Type BR, 120/240 V, 20 A, Number of Phases: 1, Number of Poles: 1, Interrupt Rating: 10 kA, Actuator Type: Magnetic, Thermal, Trip Type: Instantaneous, Long Time, Wire Size: 14 to 8 AWG, Pigtail Mounting, Dimensions: 6 in L x 3-1/2 in W x 1-1/4 in H, Suitable for: EATON Type BR Loadcenters
Siemens Q115DF Circuit Breaker, AFCI, GFCI, 15 A, 1 -Pole, 120 V, Instantaneous, Non-Interchangeable Trip, Black
Wholesale Price:
(Members Only)
Siemens Circuit Breaker, AFCI, GFCI, 120 V, 15 A, 1 ph, 1 Pole, 10 kA Interrupt, Magnetic, Thermal Actuator, Instantaneous, Non-Interchangeable Trip, Trip Sensitivity: 5 mA, 12 to 8, 14 to 8 AWG Wire, Lug Terminal, Plug Mounting, Black, Dimensions: 3 in W x 1 in D x 4-1/2 in H
1
2